Fracturings chemicals usa Finoric Fracturing stimulation production coil tubing chemicals
Call Toll-Free: 1-855-FINORIC
Houston, Midland & Pleasanton, Texas, USA.
Email: info@finoric.com

Home - Product CAS - Contact

Search our website here

SDS MSDS Sheet of Encapsulated Gel Breaker, Controlled Release Oxidizer

FInOrIC, etymologically derived from our business line of Fine Inorganic, Organic and Industrial Chemicals, is the internationally preferred source for Chemicals. With customers in 55 countries across 5 continents, we source and sell most chemicals. Backed by owned full fledged chemical manufacturing facilities in Midland & Houston Area Texas  with associated manufacturing sites in India, Dubai, China and USA we are a truly multi-national chemical manufacturer & distributor. Fracturing and Fracking Industry can rely on our 24x7 - 365days service including week-end deliveries.

Most of our or our partner facilities are either FDA-cGMP certified, ISO-9001:2008 certified, Halal and/or Kosher certified, REACH pre-registered ISO-22000:2005 HACCP.

Bg Jar Chemical Toll Packaging & Contract Packaging Palletized and Shrink Wrapped Drum Packing Palletized and Shrink Wrapped 25kg 50kg 55 lbs Export Import Chemical Solvent Tote USA Chemical Manufacturers Carboy Bulk Jumbo Bags

Metalized Pouch Liquid Powder Pillow Pouch Sample Bottle Pouch with Cap Varous tub jar packing Pail Packing

Specifications of Encapsulated Gel Breaker for Guar in Fracturing or Fracking of Oil Well

Oxidizing Gel Breaker
Quick & Controlled Release
Gel Breaker Encapsulated for Oil Well Fracturing

Encapsulated Gel Breaker SDS, MSDS Sheet Material Safety Data Sheet

1. Product Identification

Synonyms: Encapsulated Ammonium Persulfate, Coated Gel Breaker
CAS No.: Mixture.
Molecular Weight: Not applicable
Chemical Formula: Not applicable
Intended Use
: Oil & Gas Exploration. Breaking of Gaur Gum Gel in Oil well drilling fracking or fracturing.

SUPPLIER
Company: Finoric LLC
Address: 8115 Loop 540, Beasley, Texas, 77417 USA

In case of emergency contact: Contract No: 104662
InfoTrac
US: 1-800-535-5053 
International: 352-323-3500

2. Hazards Identification

GHS, Globally Harmonized System Classification in accordance with 29 CFR 1910
Classification according to Regulation (EC) No 1272/2008

Acute toxicity - Oral Category 4
Skin corrosion/irritation Category 2
Serious eye damage/eye irritation Category 2A
Respiratory sensitization Category 1
Skin sensitization Category 1
Specific target organ toxicity (single exposure), Respiratory tract Category 3
Oxidizing Solids Category 3

Labeling according to GHS USA & Regulation (EC) No 1272/2008

GHS Label Elements
Oxidizing Solid
Oxidizing Solid
GHS Label Elements
Irritant
Irritant
GHS Label Elements
Health Hazard
Health Hazard

Signal Words: Danger

Hazard Statements:
H272: May intensify fire; oxidizer
H302: Harmful if swallowed
H315 : Causes skin irritation
H317: May cause an allergic skin reaction
H319: Causes serious eye irritation
H335: May cause respiratory irritation

Precautionary Statements - Prevention:
P210: Keep away from heat/sparks/open flames/hot surfaces. - No smoking.
P220: Keep/Store away from clothing/other combustible materials
P221: Take any precaution to avoid mixing with combustibles.
P260: Do not breathe dust/fume/gas/mist/vapors/spray
P264: Wash ... thoroughly after handling
P270: Do no eat, drink or smoke when using this product
P271: Use only outdoors or in a well-ventilated area.
P280-Wear protective gloves/protective clothing/eye protection/face protection.
P285: In case of inadequate ventilation wear respiratory protection.
Precautionary Statements - Response:
P301 + P312: IF SWALLOWED: Call a POISON CENTER or doctor if you feel unwell.
P302 + P352: IF ON SKIN: Wash with plenty of water.
P304 + P341: IF INHALED: If breathing is difficult, remove to fresh air and keep at rest in a position comfortable for breathing.
P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P314: Get Medical advice/attention if you feel unwell.
P330: If swallowed, rinse mouth.
P332+P313: If skin irritation occurs: Get medical advice/attention
P337+P313: If eye irritation persists: Get medical advice/ attention.
P360: Rinse immediately contaminated clothing and skin with plenty of water before removing clothes.
P362: Take off contaminated clothing and wash before reuse.
Precautionary Statements - Storage
P402: Store in a dry place
P403 + P233 - Store in a well-ventilated place. Keep container tightly closed
P501: Dispose of contents/container in accordance with local/regional/national/international regulations.

Classification according to EU Directives 67/548/EEC or 1999/45/EC:
O Oxidizing, Xn Harmful, Xi Irritant
R8- Contact with combustible material may cause fire.   
R22 Harmful if swallowed
R36/37/38 Irritating to eyes, respiratory system and skin
For the full text of the H-statements & R-phrases mentioned in this Section, see Section 16.

3. Composition/Information on Ingredients

Name and ----------------------- % Content CAS Number ------- EINECS EC Number
Ammonium Persulfate ----------- Less than 90 7727-54-0 ----------- EC 231-786-5
Other Non-Haz Ingredients ------ Less than 30% N/A ------------------- N/A

4. First Aid Measures

Always seek medical attention after first aid measures are provided.

Inhalation: Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.
Ingestion: If swallowed, Do not induce vomiting. Give large quantities of water. Never give anything by mouth to an unconscious person. Get medical attention immediately.
Skin Contact: In case of contact, immediately flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes. Cover the irritated skin with an emollient. Cold water may be used. Wash clothing & shoes before reuse. Get medical attention.
Eye Contact: Check for and remove any contact lenses. In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Cold water may be used. Get medical attention.

5. Fire Fighting Measures

Fire: Ammonium Persulfate and Encapsulated Gel Breaker is not combustible, but substance is a strong oxidizer and its heat of reaction with reducing agents or combustibles may cause ignition. Heating or contact with water releases oxygen which may intensify combustion in an existing fire.
Explosion: An explosion hazard when mixed with finely powdered organic matter, metal powder, or reducing agents.
Fire Extinguishing Media: Use any means suitable for extinguishing surrounding fire. Do not use water.
Special Information: In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing apparatus with full face piece operated in the pressure demand or other positive pressure mode. Sealed containers may rupture when heated.

6. Accidental Release Measures

Small Spill: Use appropriate tools to put the spilled solid in a convenient waste disposal container.
Large Spill:
It is an oxidizing material.
Stop leak if without risk. Avoid contact with a combustible material (wood, paper, oil, clothing...). Keep the substance damp using water spray. Do not touch spilled material. Prevent entry into sewers. Eliminate all ignition sources. Avoid penetration into waterways, sewers, soil or groundwater. Local authorities should be advised if significant spillages cannot be contained.

7. Handling and Storage

Keep Encapsulate Gel Breaker in a tightly closed container, stored in a cool, dry, ventilated area. Protect against physical damage. Isolate from incompatible substances. Separate from combustibles, organic or other readily oxidizable materials. Avoid storage on wood floors. Containers of this material may be hazardous when empty since they retain product residues (dust, solids); observe all warnings and precautions listed for the product.
Wear personal protective equipment. Avoid breathing dust. Handle product only in closed system or provide appropriate exhaust ventilation at machinery. Avoid contact with skin and eyes. Remove and wash contaminated clothing before re-use.

8. Exposure Controls/Personal Protection

Airborne Exposure Limits: - ACGIH Threshold Limit Value (TLV): 0.1 mg/m3 (TWA) as persulfate
Ventilation System: A system of local and/or general exhaust is recommended to keep employee exposures below the Airborne Exposure Limits. Local exhaust ventilation is generally preferred because it can control the emissions of the contaminant at its source, preventing dispersion of it into the general work area.
Personal Respirators (NIOSH Approved): For conditions of use where exposure to dust or mist is apparent and engineering controls are not feasible, a particulate respirator (NIOSH type N95 or better filters) may be worn. If oil particles (e.g. lubricants, cutting fluids, glycerin, etc.) are present, use a NIOSH type R or P filter. For emergencies or instances where the exposure levels are not known, use a full-face positive-pressure, air-supplied respirator. WARNING: Air-purifying respirators do not protect workers in oxygen-deficient atmospheres.
Skin Protection: Wear protective gloves and clean body-covering clothing.
Eye Protection: Use chemical safety goggles. Maintain eye wash fountain and quick-drench facilities in work area.

9. Physical and Chemical Properties

Appearance: Encapsulate Gel Breaker is white to off-white crystals
Odor: Mild organic odor
Solubility: Soluble
Specific Gravity: 1.75.
pH: No information found
Boiling Point: Not applicable
Melting Point: Decomposes
Vapor Density (Air=1): No information found
Vapor Pressure (mm Hg): No information found
Evaporation Rate (BuAc=1): No information found

10. Stability and Reactivity

Stability: It is stable under ordinary conditions of use and storage. Stability decreases in the presence of moisture
Hazardous Decomposition Products: Decomposed by moisture to form oxygen and ozone. Burning may produce nitrogen oxides, sulfur oxides, sulfuric acid, chlorine or hydrochloric acid and fumes.
Hazardous Polymerization: Will not occur
Incompatibilities: Reducing agents, organic material, sodium peroxide, water and powdered metals especially aluminum
Conditions to Avoid: Moisture, combustible materials and incompatibles

11. Toxicological Information

Ammonium Persulfate
Oral rat LD50: 689 mg/kg

--------\Cancer Lists\----------- -------------
-------------------------------  --NTP Carcinogen--
Ingredient ---------- Known Anticipated - IARC Category
--------------------- ----- ----------- - -----
Ammonium Persulfate - No -- No -------- - None
(7727-54-0)

12. Ecological Information

Environmental Fate: No information found.
Environmental Toxicity: No information found.

13. Disposal Considerations

Whatever cannot be saved for recovery or recycling should be handled as hazardous waste and sent to a RCRA approved waste facility. Processing, use or contamination of this product may change the waste management options. State and local disposal regulations may differ from federal disposal regulations. Dispose of container and unused contents in accordance with federal, state and local requirements.

14. Transport Information

Domestic (Land, DOT USA) & ADR/RID
Proper Shipping Name: Ammoniul Persulfate
Hazard Class: 5.1
UN/NA: UN1444
Packing Group: III

International (Water, I.M.O.)
Proper Shipping Name: Ammoniul Persulfate
Hazard Class: 5.1
UN/NA: UN1444
Packing Group: III

15. Regulatory Information

The information below is for Ammonium Persulfate:
USA:
TSCA

CAS# 7727-54-0 is listed on the TSCA inventory.
Health & Safety Reporting List
None of the chemicals are on the Health & Safety Reporting List.
Chemical Test Rules
None of the chemicals in this product are under a Chemical Test Rule.
Section 12b
None of the chemicals are listed under TSCA Section 12b.
TSCA Significant New Use Rule
None of the chemicals in this material have a SNUR under TSCA.
SARA
CERCLA Hazardous Substances and corresponding RQs

None of the chemicals in this material have an RQ.
SARA Section 302 Extremely Hazardous Substances
None of the chemicals in this product have a TPQ.
SARA Codes
CAS # 7727-54-0: acute, reactive.
Section 313
No chemicals are reportable under Section 313.

CAS# 7727-54-0 can be found on the following state right to know lists: New Jersey, Pennsylvania.
California No Significant Risk Level: None of the chemicals in this product are listed.

WHMIS (Canada):
C - Oxidizing materials
D2A - Very toxic materials
D2B - Toxic materials
Ingredient Disclosure List: Listed

Australian Hazchem Code: 2P
Poison Schedule: None allocated.

The polymer component is not classed as hazardous or toxic substance.

16. Other Information

European Labeling in Accordance with EC Directives
H272: May intensify fire; oxidizer
H302: Harmful if swallowed
H315 : Causes skin irritation
H317: May cause an allergic skin reaction
H319: Causes serious eye irritation
H335: May cause respiratory irritation

O Oxidizing
Xn Harmful
Xi Irritant
R8- Contact with combustible material may cause fire.   
R22 Harmful if swallowed.
R36/37/38 Irritating to eyes, respiratory system and skin.
S22- Do not breathe dust.
S24- Avoid contact with skin.
S26- In case of contact with eyes, rinse immediately with plenty of water and seek medical advice.
S37- Wear suitable gloves.

Prepared by AJK on 15 August 2016

DISCLAIMER: The information and recommendations set forth herein (hereinafter "Information") are presented in good faith and believed correct as of the date hereof. It is compiled from various sources and it is not necessarily all inclusive nor fully adequate in every circumstance. In addition, these suggestions should not be confused with nor followed in violation of applicable laws, regulations, rules or insurance requirements applicable. This MSDS sheet is intended only as a guide to the appropriate precautionary handling of the material by a properly trained person using this product. Individuals receiving the information must exercise their independent judgment in determining its appropriateness for a particular purpose.

Oxidizing Gel Breaker Manufacturers:

Finoric LLC
Houston, Midland & Pleasanton, Texas, USA.

Tel: 1-855-346-6742 (1-855-FINORIC)
Email:
info@finoric.com

Most products offered from our Houston & Midland Texas area warehouse

We solicit inquiries for processing (blending, making solutions, sieving) & re-bagging needs at our Houston & Midland facility on toll manufacturing basis.
We are looking for Technical Sales Representatives or Business Associates in New York, Chicago, Williston North Dakota, Mansfield Pennsylvania, Zanesville, Ohio and Los Angeles Area, USA.

Oil Drilling Fracking or Fracturing Chemicals
Ammonium Persulfate Acetic Acid
ATMP Phosphonate, Amino tris (methylene phosphonic acid)  
Citric Acid Clay Stabilizer
Encapsulated Gel Breaker Glycerin
Boron and Zirconium based Guar Cross Linkers Diverting Agent
Friction Reducer  
Glutaraldehyde Solution Hydroxy ethylidene Diphosphonic Acid, HEDP Phosphonate
Hydrogen Sulfide Scavenger Phthalic Acid
Phthalic Anhydride Potassium chloride KCl substitute
Potassium salt of Hydroxy Ethylidene,1-Diphosphonic Acid, HEDP-Kx Oil well fracturing drilling Biocide
Didecyl Dimethyl Ammonium Chloride Tetrakis (Hydroxy methyl) Phosphonium Sulfate THPS
Scale Inhibitor BHMT Phosphonate or BHMTPMPA
Sodium Glutaraldehyde Bisulfite Bisulphite Calcium Chloride Anhydrous
Calcium Chloride Dihydrate & Hexahydrate & Solution. Sodium Chlorite Solution
Sodium Acetate Anhydrous & Sodium Acetate Trihydrate Potassium Chloride
Zinc Chloride  

Palletized and Shrink Wrapped 25kg 50kg 55 lbs Export Import Palletized and Shrink Wrapped Drum Packing Gel Breaker Encapsulated for Oil Well Fracturing Fracking Drilling

12 April, 2017